Sunday, May 24, 2020

2010 Cadillac Truck SRX AWD V6-2.8L Turbo Page 242

2010 Cadillac Truck SRX AWD V6-2.8L Turbo Page 242



3. Verify that DTC B0183 02 or B0183 05 is not set.



瀚慖f DTC is present, refer to Sunload Sensor Circuit Malfunction.



4. Measure actual inside air temperature using a thermometer. Compare this value to the scan tool Passenger Compartment Air Temperature



parameter. The measured temperature should be within 5掳C (9掳F) difference of parameter value.



瀚慖f not within the specified range, replace the B10B Ambient Light/Sunload Sensor.



Circuit/System Testing



Ambient Light/Sunload Sensor Power Supply Malfunction



1. Ignition OFF, disconnect the harness connector at the B10B Ambient Light/Sunload Sensor.



2. Test for less than 10 ohm between the B10B Ambient Light/Sunload Sensor ground circuit terminal 6 and ground.



瀚慖f greater than the specified range, test the ground circuit for an open/high resistance. If the circuit tests normal, replace the K33 HVAC



Control Module.



3. Ignition ON, test for battery voltage between the reference voltage circuit terminal 2 and ground.



瀚慖f greater than the specified range, test the reference voltage circuit for an open or short to ground. If the circuit tests normal, replace the



K33 HVAC Control Module.



4. If all circuits test normal, replace the B10B Ambient Light/Sunload Sensor.



Passenger Compartment Temperature Sensor Circuit Malfunction



1. Ignition OFF, disconnect the harness connector at the B10B Ambient Light/Sunload Sensor.



2. Ignition ON, test for 4.8-5.2 V between the signal circuit terminal 3 and ground.



瀚慖f less than the specified range, test the signal circuit terminal for a short to ground or open/high resistance. If the circuit tests normal,



replace the K33 HVAC Control Module.



瀚慖f greater than the specified range, test the signal circuit terminal for a short to battery. If the circuit tests normal, replace the K33 HVAC



Control Module.



3. If all circuits test normal, replace the B10B Ambient Light/Sunload Sensor.



Sunload Sensor Circuit Malfunction



1. Ignition OFF, disconnect the harness connector at the B10B Ambient Light/Sunload Sensor.



2. Ignition ON, test for 4.8-5.2 V between the signal circuit terminal 4 and ground.



瀚慖f less than the specified range, test the signal circuit terminal for a short to ground or open/high resistance. If the circuit tests normal,



replace the K33 HVAC Control Module.



瀚慖f greater than the specified range, test the signal circuit terminal for a short to battery. If the circuit tests normal, replace the K33 HVAC



Control Module.



3. If all circuits test normal, replace the B10B Ambient Light/Sunload Sensor.



Repair Instructions



Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic procedure.



* HVAC Component Replacement Reference (See: Heating and Air Conditioning/Service and Repair/Removal and Replacement)



* Control Module References (See: Testing and Inspection/Programming and Relearning) for HVAC control module replacement, setup, and



programming



B0173



DTC B0173, B0178, B0509, B0514, B0519, B3583, or B3933



Diagnostic Instructions



* Perform the Diagnostic System Check - Vehicle (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic System



Check - Vehicle) prior to using this diagnostic procedure.



* Review Strategy Based Diagnosis (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Strategy Based Diagnosis) for an



overview of the diagnostic approach.



* Diagnostic Procedure Instructions (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic Procedure



Instructions) provides an overview of each diagnostic category.