Friday, March 27, 2020

2010 Cadillac Truck SRX AWD V6-2.8L Turbo Page 420

2010 Cadillac Truck SRX AWD V6-2.8L Turbo Page 420



DTC B097B 02



- Power Mode Start Switch Circuit Short to Ground



DTC B097B 04



- Power Mode Start Switch Circuit Open



DTC B097B 08



- Power Mode Start Switch Circuit Performance - Signal Invalid



DTC B097B 61



- Power Mode Start Switch Circuit - Stuck



DTC B097C 01



- Power Mode Run/Start Circuit Indicator Short to Battery



DTC B097C 02



- Power Mode Run/Start Circuit Indicator Short to Ground



DTC B097C 04



- Power Mode Run/Start Indicator Circuit Open



Circuit/System Description



The ignition mode switch has 2 LED's that indicate the vehicle power mode. When the vehicle is in the off mode, both LED's will be off. Pressing



the ignition mode switch button once (without the brake pedal applied), the vehicle enters the accessory mode and the amber LED (ACC) will



illuminate. Pressing the ignition mode switch button a second time (without the brake pedal applied), the vehicle enters the run/start mode (without



the engine running) and the green LED (Run/Start) will illuminate. With the ignition off (with the brake pedal applied), pressing the ignition mode



switch button once, the vehicle will enter run/start mode and the green LED (run/start) will illuminate. This will start the engine. Both LED's have



the voltage supplied from the body control module (BCM). The ignition mode switch sends the ignition mode switch status to the passive entry



passive start module (PEPS) and to the BCM. The PEPS module sends a redundant signal to the BCM with the ignition mode switch status.



Conditions for Running the DTC



Voltage supplied to the module is in the normal operating voltage range of 9-16 V.



Conditions for Setting the DTC



B0978, B097C 01



* The BCM detects a short to battery in the respective indicator control circuit, when the output is active.



* The above condition exists for more than 1 second.



B0978, B097B, B097C 02



* The BCM detects a short to ground in the respective circuit, when the output is inactive.



* The above condition exists for more than 1 second.



B0978, B097B, B097C 04



* The BCM detects an open in the respective circuit, when the output is inactive.



* The above condition exists for more than 1 second.



B097B 00



* The BCM detects a difference between the ignition mode switch voltages to the BCM and PEPS module.



* The above condition exists for more than 1 second.



B097B 08



* The BCM detects a difference between the ignition mode switch voltages to the BCM and PEPS module.



* The above condition exists for more than 1 second.



B097B 61



* The BCM and the PEPS module detect a continuously closed ignition mode switch.



* The above condition exists for more than 1 minute.



Action Taken When the DTC Sets



The BCM disables the respective output until the next ignition cycle.



Conditions for Clearing the DTC



* A current DTC clears when the malfunction is no longer present.



* A history DTC clears when the module ignition cycle counter reaches the reset threshold, without a repeat of the malfunction.